beautypg.com

HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 312

background image


01.98

TNC 407/TNC 415/TNC 425

9 Touch probe

4-187

Procedure for optimizing machine parameters

Connect a storage oscilloscope to the nominal
command input of the servo amplifier for the
X axis.

In the

"PROGRAM RUN/FULL SEQUENCE"
mode, select OPTIDIGI program and operate

the external START KEY.
Machine runs, digitizing starts.

U[V]

Increase the feedrate [1] with the override

potentiometer until X nominal command attains.
maximum value and shows only minor voltage

dips (axis should just still traverse at even

speed).

Umax

t[s]

Decrement Mp6230 again
(e.g. by 10 mm/min)

Repeat optimizing sequence for Y axis.

Switch the NC program to scanning

direction Y [2].

Repeat optimizing sequence for Z axis.
Change the scanning range accordingly.
Pay particular attention to vertical face.

Increment MP6230
(e.g. by 10 mm/min)

yes

no

Are oscillations in

normal direction visible

(stylus tip is seen to lift off

workpiece surface)?

[1] Keep a note of the maximum
feedrate that is possible in the

worst axis.

[2] The optimizing sequence is
geared to the worst axis. This is
why the feedrate must not be further
increased with the override