The specified color refers to one of the machine parameters MP735x and can be seen from the
following table:
Color 0: MP736x.0 depending on the displayed graphics
Color 1: MP7354.0
Color 2: MP7356.0
Color 3: MP7352.0
Color 4: MP7353.0
Color 5: MP7357.0
Color 6: MP7352.1
Color 7: MP7353.1
Color 8: MP7350
Color 9: MP7357.1
Color 10: MP7354.1
Color 11: MP7356.2
Color 12: MP7356.1
Color 13: MP7354.2
Color 14: MP7352.2
Color 15: MP7351
Color 2 is the background color for the screen window and can be used for margin and scale
graduations if these are not to be displayed. If no screen window is currently shown for the PLC
status display (window is not opened or in background) the module will cycle normally and the bar
chart will not be displayed until the corresponding screen window reappears and provided the chart
is not overwritten by a repeat call of Module 9083 in the meantime. Module 9081 can be used to
check whether the display is currently active. This job cannot be aborted by a CAN command during
processing of the module in a SUBMIT Job.
Possible errors:
- The module was not called from a SUBMIT Job.
- A line less than 0 or greater than 1 was specified.
The bar chart is not displayed on screen in any of these error modes.
Call:
PS
K/B/W/D
Line number (0...1)
PS
K/B/W/D
Color for bar (0...15)
PS
K/B/W/D
Color for frame and scale graduation (0...15)
PS
K/B/W/D
Current length of bar (0...150)
PS
K/B/W/D
Maximum length of bar (0...150)
CM
9083
Error status after call: M3171 =
0: String displayed (when screen window for PLC status is
displayed)
1: No display, error condition see above