beautypg.com

10 user-parameters, 11 code-numbers – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 277

background image


4-152

TNC 407/TNC 415/TNC 425

6 Display and operation

01.98

6.10 User-parameters

With the MOD-function up to 16 different machine parameters can be made accessible to the
machine operator as User-parameters. The machine manufacturer determines in machine parameter
MP7330.x which machine parameters are to be defined as User-parameters. If, for example, you
wish to define MP5030.1 as the first user-parameter, you must enter the value 5030.01 in MP
7330.0.

If a User-parameter is selected by the operator, a dialogue appears on the screen. Machine
parameter MP7340.X determines which dialogue should be displayed. A line number from the PLC
dialogues is defined with an entry value between 0 and 4095 (see "PLC description").

MP7330

Determination of the User-Parameters
Entry range: 0 to 9999.00 (No. of the desired machine parameters).

MP7330.0

User-parameter 0

MP7330.1

User-parameter 1

.

.

.

.

MP7330.14

User-parameter 14

MP7330.15

User-parameter 15

MP7340

Dialogues for User-parameter
Entry:0 to 4095 (line number of the PLC dialogs)

MP7340.0

Dialogue for User-parameter 0

MP7340.1

Dialogue for User-parameter 1

.

.

.

.

MP7340.14

Dialogue for User-parameter 14

MP7340.15

Dialogue for User-parameter 15

6.11 Code-numbers

The MOD functions can be used to enter code-numbers for the control. These code numbers can be
used to activate certain control functions.
The following code-numbers have a fixed meaning:

Code-number

Function

95 148

Select machine parameter list

807 667

Select PLC mode

105 296

Correction tables for the non-linear axis-error compensation

86 357

Remove program protection

75 368

Automatic offset adjustment

123

Select the user-available list of machine parameters

531 210

Erase markers M1000 to M2000 and byte 0 to byte 127
Special function: Switch on control and press MOD key at the same time. Enter
code number. The entire RAM memory is now erased (MPs, NC programs, PLC
program, all markers and bytes).

688 379

Oscilloscope