background image


01.98

TNC 407/TNC 415/TNC 425

6 Display and operation

4-127

RM

RM

RM

Workpiece datum

Scale reference point

RM = Reference mark

Machine datum

MP950

Datum point for positioning blocks with M92
Entry: –99 999.999 to +99 999.999 [mm] or [°]
Values referenced to the machine datum

MP950.0

X axis

MP950.1

Y axis

MP950.2

Z axis

MP950.3

4th axis

MP950.4

5th axis

MP960

Machine datum
Entry: –99 999.999 to +99 999.999 [mm] or [°]
Values referenced to the measuring system datum

MP960.0

X axis

MP960.1

Y axis

MP960.2

Z axis

MP960.3

4th axis

MP960.4

5th axis

MP7295

Disable "set datum point"
Entry: %xxxxx

Bit 0

X axis

0 = not disabled

Bit 1

Y axis

1 = disabled

Bit 2

Z axis

Bit 3

4th axis

Bit 4

5th axis