Vertical zoom

The vertical grid display of each previously selected channel can be modified in fixed steps using
soft keys. The value of the grid in the vertical axis is overlaid at the left hand margin beneath the
channel number and the name of the recording.

Centring

Select vertical resolution to achieve an optimum display.

Now return to original vertical deflection: use the NO ENT key to restore the original display of the
stored data in the vertical axis.

Horizontal zoom

The recording gathers 4096 evaluated data. Time resolution, i.e., the cycle time between the
recorded data, can be set from 0.6 to 6 ms. The range of display stretching and condensing is
limited as follows.

Evaluated data

Data : Pixels

smallest display

4096

8 : 1

max. stretched display

64

1 : 8