beautypg.com

Analogue output, 4 analogue output – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 721

background image


01.98

TNC 407/TNC 415/TNC 425

2 Mounting and electrical installation

11-7

2.3.3 Connection of rotary encoder for spindle orientation

The encoder for oriented spindle stop is connected at the input X6 (square-wave signals).
Max. input frequency: 300 kHz

HEIDENHAIN recommends using the ROD 426.xxx8 (1024 lines).

Cable adapter, complete

(Max. 20 m)

Connector (female) 12-pin / D-sub connector (pin) 15-pin

Id.-Nr. 267 268 ..

or

Connecting cable with one connector

(Max. 20 m)

D-sub connector (pin) 15-pin

Id.-Nr. 268 372 ..

2.4 Analogue output

The TNC 425 from HEIDENHAIN permits installation of commercially standard amplifiers and motors
with AC technology. The output with the analogue nominal value voltage of the TNC's rpm controller
is connected with the torque input of the servo amplifier.

This drive concept eliminates the need for tachogenerators. The rpm actual value is measured by a
HEIDENHAIN incremental rotary encoder.