5 error messages, Tnc error messages, 5 error messages 5.1 tnc error messages – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 695

8-48
TNC 407/TNC 415/TNC 425
5 Error messages
01.98
5 Error messages
5.1
TNC error messages
Listed below are the error messages for data transfer, which are displayed at the TNC. In most
cases the messages are self-explanatory.
General error messages:
BAUD RATE NOT POSSIBLE
One interface is configured for 19,200 baud and the other
for 38,400 baud.
INTERFACE ALREADY ASSIGNED
Transfer is already taking place via interface, or data transfer
has not been completed.
PROGRAM INCOMPLETE
A transfer has been interrupted or the file has not ended
correctly (no END character or END block).
EXT. OUTPUT/INPUT NOT READY
Interface is not connected; peripheral unit is switched off of
faulty.
TRANSFERRED DATA INCORRECT X
X can assume the values A to H, K or L (error codes).
Error codes:
E
During data transfer with Block Check Character (BCC), a (
three times in sequence.
A to H
except
E
The receiving component has detected an error with one of the following causes:
– Same baud rate not set at TNC and peripheral unit
– Parity bit wrong
– Incorrect data frame (e.g. no stop bit)
– Receiving component of interface faulty
K
During the transmission of an error to the TNC the <1> character was not transmitted
after the
L
An incorrect error number was received after the
numbers 0 to 7 are permitted).
N
An expected
time.
M
For data transmission with BCC,
Error codes K and L are displayed only for transfer with standard data transmission protocol.
Error messages occurring only in ME-mode:
WRONG OPERATING MODE
TRANSFERRED DATA INCORRECT
WRONG PROGRAM DATA
ME: TAPE END
DATA MEDIUM MISSING
DATA MEDIUM EMPTY
DATA MEDIUM WRITE-PROTECTED