beautypg.com

5 error messages, Tnc error messages, 5 error messages 5.1 tnc error messages – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 695

background image


8-48

TNC 407/TNC 415/TNC 425

5 Error messages

01.98

5 Error messages

5.1

TNC error messages

Listed below are the error messages for data transfer, which are displayed at the TNC. In most
cases the messages are self-explanatory.

General error messages:

BAUD RATE NOT POSSIBLE

One interface is configured for 19,200 baud and the other
for 38,400 baud.

INTERFACE ALREADY ASSIGNED

Transfer is already taking place via interface, or data transfer
has not been completed.

PROGRAM INCOMPLETE

A transfer has been interrupted or the file has not ended
correctly (no END character or END block).

EXT. OUTPUT/INPUT NOT READY

Interface is not connected; peripheral unit is switched off of
faulty.

TRANSFERRED DATA INCORRECT X

X can assume the values A to H, K or L (error codes).

Error codes:

E

During data transfer with Block Check Character (BCC), a () has been received
three times in sequence.

A to H
except
E

The receiving component has detected an error with one of the following causes:
– Same baud rate not set at TNC and peripheral unit
– Parity bit wrong
– Incorrect data frame (e.g. no stop bit)
– Receiving component of interface faulty

K

During the transmission of an error to the TNC the <1> character was not transmitted
after the character.

L

An incorrect error number was received after the <1> error sequence (error
numbers 0 to 7 are permitted).

N

An expected or acknowledgement was not transmitted within a certain
time.

M

For data transmission with BCC, was transmitted three times in sequence.

Error codes K and L are displayed only for transfer with standard data transmission protocol.

Error messages occurring only in ME-mode:

WRONG OPERATING MODE
TRANSFERRED DATA INCORRECT
WRONG PROGRAM DATA
ME: TAPE END
DATA MEDIUM MISSING
DATA MEDIUM EMPTY
DATA MEDIUM WRITE-PROTECTED