3.6 Spindle
Machine
parameter
Function and input
Change
via
Reaction
Page
Spindle-speed output, Spindle orientation
Entry: 0 to 8
0 = No spindle-speed output
1 = BCD-coded output of the spindle speed,
only if the spindle speed changes
2 = BCD-coded output of the spindle-speed
3 = Analogue output of the spindle speed, but
gear-change signal only if the gear range
changes
4 = Analogue output of the spindle speed and
gear-change signal at every TOOL CALL
5 = Analogue output of the spindle speed and
6 = As for entry value 3, but with controlled
7 = As for entry value 4, but with controlled
8 = As for entry value 5, but with controlled
Function of analogue output S if MP3010 < 3
Entry: 0 to 2
0 = No special function
1 = Voltage proportional to current contour feed
2 = Voltage as defined by PLC module 9130
3 = Voltage as defined via M function (M200 to
Feed-rate for output of an analogue voltage of 10 V
(MP3011 = 1)
Entry: 0 to 300 000 [mm/min]
Characteristic curve kink points for analogue
voltage output with M202
Entry: 10 to 300 000 [mm/min]
Characteristic curve kink points for analogue
voltage output with M202
Entry: 0.000 to 9.999 [V]