HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 401
17 Special functions for laser cutting machines
MP3013.0 to
Characteristic kink points for analogue voltage output with M202
MP3013.11
Entry:
10 to 300 000 [mm/min]
MP3014.0 to
Characteristic kink points for analogue voltage output with M202
MP3014.11
Entry:
0.000 to 9.999 [V]
Voltage varies with the time (time-voltage ramp): M203 V... TIME...
The TNC outputs the voltage as a function of the time. It increases or decreases the voltage linearly in
the time programmed behind TIME from the current voltage to the voltage value programmed behind
V...
Entry:
Voltage V:
0 to 9.999 [V]
TIME:
0 to 1.999 [sec]
Duration:
M203 V... TIME... is effective until a new voltage is output through M200 to M204.
Voltage for a specific time (time pulse): M204 V... TIME...
The TNC outputs the voltage programmed behind V... as a pulse. The duration of the pulse is entered
with TIME....
Entry:
Voltage V:
0 to 9.999 [V]
TIME:
0 to 1.999 [sec]
Duration:
M204 V... TIME... is effective until a new voltage is output through M200 to M204.