4 or not (on) – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 520

7-59
3.3.4 OR NOT (ON)
Abbreviation for the PLC-Editor:
ON (OR NOT)
Logic
Byte/Word
Double
Constant
Execution time [µs]
0.5 to 0.9
0.5 to 0.9
0.5 to 0.9
0.2 to 0.5
Number of bytes
8
8
8
10
Logic execution with the OR NOT command
Operands: M, I, O, T, C
Operation:
This command functions in different ways according to its position in the program:
a) At the start of a logic chain this command functions as an LN command, i.e. the complement of
the operand is loaded into the Logic Accumulator. This is to ensure compatibility with the TNC 355
control which did not have the special LN command. In PLC programs for the TNC 407/TNC 415 a
logic chain should always be started with a load command (see L, LN, L–).
b) Within a logic chain, the contents of the Logic Accumulator and the logic state of the operand
(M, I, O, T, C) are gated with OR NOT. The result of the operation is stored in the Logic
Accumulator.
Example:
Input I4 and Input I5 are to be gated with OR NOT and the result assigned to Output O2.
Initial state:
Input
I4
= 0
Input
I5
= 0
Output O2
= ?
Line Instruction
Accumulator Contents
Operand Contents
Bit
31
.
.
.
7
0
... x x x x x x x x x x x x x x
1
L I4
... x x x x x x 0 x x x x x x x
0
2
ON I5
... x x x x x x 1 x x x x x x x
0
3
= O2
... x x x x x x 1 x x x x x x x
1
Line 1:
The operand contents are loaded into the Accumulator.
Line 2:
The contents of the Logic Accumulator and Input I5 are gated with OR NOT.
Line 3:
The gating result is assigned to Output O2.