2.2 Summary of connections
X43
X47
X42 X46
X41 X45
X44
X21
X22
X23
X14
X1
X15
X2
X3
X4
X5
X6
X12
X20
X19
X8
X18
X17
X16
Control loop board
X1 = Encoder 1 (~)
X2 = Encoder 2 (~)
X3 = Encoder 3 (~)
X4 = Encoder 4 (~)
X5 = Encoder 5 (~)
X6 = Encoder S ( )
X8 = Nominal value output 1,2,3,4,5,S
X12 = Triggering touch probe system
X14 = Measuring touch probe system
X15 = Encoder/speed
X16 = Encoder/speed
X17 = Encoder/speed
X18 = Encoder/speed
X19 = Encoder/speed
X20 = Spare
B
PLC and Graphics Board
X41 = PLC outputs
X42 = PLC inputs
X43 = Visual display unit (BC 110)
X44 = 24 V supply for PLC
X45 = TNC keyboard (TE)
X46 = Machine control panel
X47 = PLC I/O unit (PL)
Processor Board
X21 = RS-232-C/V.24 data interface
X22 = RS-422/V.11 data interface
X23 = Handwheel
X31 = 24 V