4-270
TNC 407/TNC 415/TNC 425 16 Commissioning and start-up procedure 01.98

Optimize transient response

MP1520 defines the transient response when accelerating and braking. The approach behaviour is
optimized to the target position.

U [V]

t [ms]

Tacho
voltage

MP1530 correct

MP1530 too high

MP1530 too low

Since MP1520 is effective for all axes, the worst axis determines the entry value. No axis should
show an overshoot.

If MP1520 is set too low then the positioning times to the target position will increase substantially.
Optimize MP1520 with great care!