beautypg.com

4 non-implemented markers – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 646

background image


01.98

TNC 407/TNC 415/TNC 425

5 Compatibility with TNC 355

7-185

5.3.4 Non-Implemented Markers

Marker

Function

M2020

Spindle speed under-ranged

M2021

Nominal/actual speed difference over-ranged

M2024

Touch probe ready

M2049

Mode : Background Programming

M2050

Mode: Programming & Editing

M2056

Mode: Test program

M2060

DIN/ISO Programming

M2062

"Code number" dialog

M2063

Central tool file

M2188

Checksum error for non-volatile Q parameters

M2288

X axis was moving when program aborted

M2289

Y axis was moving when program aborted

M2290

Z axis was moving when program aborted

M2291

Axis 4 was moving when program aborted

M2292

Axis 5 was moving when program aborted

M2504

Axis clamping after constant contour transition

M2509

Activate a % factor for feed rate over-ride

M2510

Deactivate spindle over-ride

M2511

Deactivate feed rate over-ride

M2526

Switch X/Y or Z to 4th axis

M2542

Complement for M2526

M2585

PLC positioning axis S (lsb)

M2586

PLC positioning axis S

M2587

PLC positioning axis S

M2588

PLC positioning axis S

M2589

PLC positioning axis S (msb)

M2590

Define the axis to be switched to 4th axis (lsb)

M2591

Define the axis to be switched to 4th axis (msb)

M2592

Tool number from M2560 to M2567

M2593

Go to Hirth grid after NC STOP

M2594

Central tool file cannot be edited

M2595

Output tool number in addition to pocket number

M2596

Select central tool file during active program run mode

M2598

Transfer tool number

M2599

Transfer tool number

M2602

Define reference point traverse

M2603

Axis sequence for reference point traverse (lsb)

M2604

Axis sequence for reference point traverse

M2605

Axis sequence for reference point traverse

M2606

Axis sequence for reference point traverse

M2607

Axis sequence for reference point traverse (msb)

M2657

Display a second auxiliary function

M2664

No standstill monitoring X axis

M2665

No standstill monitoring Y axis

M2666

No standstill monitoring Z axis