01.98
TNC 407/TNC 415/TNC 425
4 Main Spindle
4-113
4.4.1 Tapping with floating tap holder for analogue spindle-speed
output
The following diagram shows the sequence of events in the cycle.
F
0
S
0
M03
M05
M04
M2482
(M03) M2485
(M04) M2486
(M05) M2487
M2048
Dwell time from
CYCL DEF 2.3
MP7120.2
30 ms
(Software-controlled)
MP3410.0
MP7120.0
MP3410.2
MP3410.0