4.3.2 Write Status Information (Module 9036)

NC status information that is not protected by a checksum can be modified. The information to be
overwritten is identified by a specified number. The following status information can be modified:

Specified
number

Function

Value

0

Handwheel interpolation X

0 to 10

1

Handwheel interpolation Y

0 to 10

2

Handwheel interpolation Z

0 to 10

3

Handwheel interpolation 4

0 to 10

4

Handwheel interpolation 5

0 to 10

5

Handwheel interpolation all axes

0 to 10

6

Select handwheel axis
(MP7640 = 0 to 4)

0 =

Axis X

1 =

Axis Y

2 =

Axis Z

3 =

4th axis

4 =

5th axis

7 to 9

Reserved

10

Limit for jog increment

0 to 50 mm = limit for jog
increment
–1,

<

–2 or

>

50 = cancel the

limit and activate the last jog
increment entered
–2 = cancel the limit and enter
the minimum of the last jog
increment and the last limit
value

Constraints:
- Handwheel subdivision factors are limited to the lowest possible value according to the rapid

traverse of the corresponding axis. There is no error message however.

- A handwheel subdivision can only be specified by MP7641=1.
- The value for the jog increment limit is transmitted in units of 1/10 000 mm
- After power switch-on the jog increment limit is always erased
- If the jog increment limit is entered in inches, the limit value [°] for rotary axes is calculated from

the limit value in millimeters divided by 24.5.

- The input parameter "Number of status information" does not identify status information that can

be overwritten in this software version.

- The specified value is outside the range valid for this status information.
- The entry of this status information is disabled, e.g. by machine parameters.

Call:

PS

B/W/D/K

PS

B/W/D/K

CM

9036

´PL

B/W/D

0: Status written
1: Wrong status identifier
2: Specified value out of range
3: Entry disabled (e.g. by MP)

Error status after call: M3171 =

0: Status was written
1: Error condition see above