HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 195

3 Servo positioning of the NC-axes
MP1810
K
v
factor for operation with lag
Entry: 0.100 to 20.000 [
m/min
mm
]
MP1810.0
k
v
factor X axis
MP1810.1
k
v
factor Y axis
MP1810.2
k
v
factor Z axis
MP1810.3
k
v
factor 4th axis
MP1810.4
k
v
factor 5th axis
MP1815
K
v
factor for operation with lag active after M105
Entry: 0.100 to 20.000 [
m/min
mm
]
MP1815.0
X axis
MP1815.1
Y axis
MP1815.2
Z axis
MP1815.3
4th axis
MP1815.4
5th axis
MP1010
Rapid traverse
Entry: 10 to 300 000 [mm/min]
MP1010.0
X axis
MP1010.1
Y axis
MP1010.2
Z axis
MP1010.3
4th axis
MP1010.4
5th axis
MP1050
Analogue voltage for rapid traverse
Entry: 1.000 to 9.000 [V]
MP1050.0
X axis
MP1050.1
Y axis
MP1050.2
Z axis
MP1050.3
4th axis
MP1050.4
5th axis
MP1020
Manual feed
Entry: 10 to 300 000 [mm/min]
MP1020.0
Manual feed X axis
MP1020.1
Manual feed Y axis
MP1020.2
Manual feed Z axis
MP1020.3
Manual feed 4th axis
MP1020.4
Manual feed 5th axis
Address
Function
D596
Rapid traverse from PLC