8-24

TNC 407/TNC 415/TNC 425

2 TNC data interfaces

01.98

Character parity
Bits 4 and 5 determine the type of parity check (see paragraph 1.1.3 "Checking data").

Stop bits
Bits 6 and 7 determine the number of stop bits sent at the end of a character.

MP 5020.0 Operating mode EXT1
MP 5020.1 Operating mode EXT2
MP 5020.2 Operating mode EXT3 (PLC)

Entry: %xxxxxxxx

Bit 07 or 8 data bits

0 = 7 data bits

1 = 8 data bits

Bit 1Block check character

0 = any BCC

1 = BCC not control character

Bit 2Transmission stop by RTS

0 = not active

1 = active

Bit 3Transmission stop by DC3 0 = not active

1 = active

Bit 4Character parity

0 = even

1 = odd

Bit 5Character parity

0 = not desired

1 = desired

Bit 6/7

Stop bits

Bit 6

Bit 7

1 1/2 stop bits

Bit

0

0

2 stop bits

Bit

1

0

1 stop bit

Bit

0

1

1 stop bit

Bit

1

1

For operating modes EXT1/EXT2/EXT3, MP5030 defines the transmission protocol.

MP5030.0

Operating mode EXT1

MP5030.1

Operating mode EXT2

MP5030.2

Operating mode EXT3 (PLC)
Entry : 0 or 1

0 = "Standard data transfer"
1 = "Transfer blockwise"