HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 222

MP3510
Spindle speed for gear ranges
Entry: 0 to 99 999.999 [rpm]
MP3510.0
Spindle speed for gear range 1
MP3510.1
Spindle speed for gear range 2
MP3510.2
Spindle speed for gear range 3
MP3510.3
Spindle speed for gear range 4
MP3510.4
Spindle speed for gear range 5
MP3510.5
Spindle speed for gear range 6
MP3510.6
Spindle speed for gear range 7
MP3510.7
Spindle speed for gear range 8
MP3515
Maximum spindle speed
Entry: 0 to 99 999.999 [rpm]
MP3515.0
Maximum spindle speed, gear range 1
MP3515.1
Maximum spindle speed, gear range 2
MP3515.2
Maximum spindle speed, gear range 3
MP3515.3
Maximum spindle speed, gear range 4
MP3515.4
Maximum spindle speed, gear range 5
MP3515.5
Maximum spindle speed, gear range 6
MP3515.6
Maximum spindle speed, gear range 7
MP3515.7
Maximum spindle speed, gear range 8
MP3210
S-analogue voltage for gear range
Entry: 0 to 9.999 [V]
MP3210.0
S-analogue voltage, gear range 1
MP3210.1
S-analogue voltage, gear range 2
MP3210.2
S-analogue voltage, gear range 3
MP3210.3
S-analogue voltage, gear range 4
MP3210.4
S-analogue voltage, gear range 5
MP3210.5
S-analogue voltage, gear range 6
MP3210.6
S-analogue voltage, gear range 7
MP3210.7
S-analogue voltage, gear range 8
MP3240.1
Minimum S-analogue voltage output
Entry: 0 to 9.999 [V]
MP3120
Zero spindle speed permitted
Entry value 0:S = 0 permitted
Entry value 1:S = 0 not permitted
MP3410.0
Ramp slope for spindle for M03, M04, M05
Entry: 0 to 1.9999 [V/ms]
Marker
Function
Set
Reset
M2004
S-analogue voltage not on the ramp
NC
NC
M2005
S-analogue voltage = 0 V
NC
NC