4-188

TNC 407/TNC 415/TNC 425

9 Touch probe

01.98

Calculation of possible oscillations in normal direction

MP 6210 [1/s] =

optimised F [mm / min]

PP.INT [mm] x 60 [s / min]

1)

2)

When the calculated machine parameter MP 6210 is entered the feed override potentiometer is
trimmed to the "attained feed rate".

1)

Maximum possible feed rate noted during optimizing

2)

PP.INT is the programmed maximum probe point interval from the "Meander" scanning
cycle (in the example, PP.INT = 1 mm).