; READ MACHINE PARAMETERS
LBL 41
RPLY B238
== K+0 ;POLL ALREADY RUNNING
JPF 11 ;END OF MODULE
SUBM 45 ;READ MP
= B238 ;STORE IDENTIFIER
EM
LBL 45
PS K+810 ;MP NUMBER (MODULO VALUE)
PS K+4 ;MP INDEX
CM 9032 ;CALL MODULE
PL D232 ;STORE (SEQUENCE LENGTH)
PS K+7261 ;MP NUMBER (NUMBER OF TOOLS E
WITH POCKET NUMBER
PS K+0 ;INDEX
CM 9032 ;CALL MODULE
PL W230 ;STORE (NUMBER OF
TOOLS WITH POCKET NUMBER)F
EM
; APPROACH REFERENCE MARKS FOR PLC AXIS
LBL 42 ;
PS K+4 ;PLC AXIS
PS D772 ;FEED-RATE
PS K+0 ;POSITIVE TRAVERSE DIRECTION
CM 9123 ;START REF TRAVERSE
L M599 ;LOG ONE
R M544 ;REF TRAVERSE OF PLC AXIS
EM