beautypg.com

HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 429

background image


01.98

TNC 407/TNC 415/TNC 425

3 List of machine parameters

5-27

Machine
parameter

Function and input

Change
via

Reaction

Page

MP5040

Data transfer rate in operating mode EXT3
(data transfer via PLC)
Entry: 0 to 9

0 =

110 baud

5 =

2

400 baud

1 =

150 baud

6 =

4

800 baud

2 =

300 baud

7 =

9

600 baud

3 =

600 baud

8 = 19

200 baud

4 = 1200 baud

9 = 38

400 baud

PLC RUN

8-47

MP5200
MP5200.0
MP5200.1
MP5200.2

Control character for beginning of text (STX)
in operating mode EXT 1
in operating mode EXT 2
in operating mode EXT 3 (PLC)
Entry: 0 to 127

PLC RUN
CN 123

8-25

MP5201
MP5201.0
MP5201.1
MP5201.2

Control character for end of text (ETX)
in operating mode EXT 1
in operating mode EXT 2
in operating mode EXT 3 (PLC)
Entry: 0 to 127

PLC RUN
CN 123

8-25

MP5202
MP5202.0
MP5202.1
MP5202.2

ASCII character for file type for data entry
in operating mode EXT 1
in operating mode EXT 2
in operating mode EXT 3 (PLC)
Entry: 0 to 127

PLC RUN
CN 123

8-26

MP5203
MP5203.0
MP5203.1
MP5203.2

ASCII character for input identification (E)
in operating mode EXT 1
in operating mode EXT 2
in operating mode EXT 3 (PLC)
Entry: 0 to 127

PLC RUN
CN 123

8-26

MP5204
MP5204.0
MP5204.1
MP5204.2

ASCII character for file type for data output
in operating mode EXT 1
in operating mode EXT 2
in operating mode EXT 3 (PLC)
Entry: 0 to 127

PLC RUN
CN 123

8-26

MP5205
MP5205.0
MP5205.1
MP5205.2

ASCII character for output identification (A)
in operating mode EXT 1
in operating mode EXT 2
in operating mode EXT 3 (PLC)
Entry: 0 to 127

PLC RUN
CN 123

8-26

MP5206
MP5206.0
MP5206.1
MP5206.2

ASCII characters for start of heading (SOH)
in operating mode EXT 1
in operating mode EXT 2
in operating mode EXT 3 (PLC)
Entry: 0 to 127

PLC RUN
CN 123

8-25