2 current tool axis, 3 vdu display – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 139

MP120
Assignment of the analogue outputs
Entry:
0 = output 1
1 = output 2
2 = output 3
3 = output 4
4 = output 5
5 = output S
MP120.0
X axis
MP120.1
Y axis
MP120.2
Z axis
MP120.3
4th axis
MP120.4
5th axis
1.2.2 Current tool axis
In the NC-block "TOOL CALL" it is determined whether the tool moves parallel to one of the principal
axes X, Y, Z or parallel to the fourth axis. The fifth axis may not be defined as a tool axis. The
markers M2100 to M2103 are used to show which of the four axes is currently defined as the tool
axis. The appropriate marker is then set.
Marker
Function
Set
Reset
M2100
X-axis is tool axis
NC
NC
M2101
Y-axis is tool axis
M2102
Z-axis is tool axis
M2103
4th axis is tool axis
1.3 VDU display
Machine parameters can be used to select which of the active axes (MP10) should be displayed in
the status window.
The spindle position is displayed only when neither M03 nor M04 is active (see under "Main
spindle").
MP40 VDU
display
Entry: %xxxxx
Bit 0
X axis
0 = not active
Bit 1
Y axis
1 = active
Bit 2
Z axis
Bit 3
4th axis
Bit 4
5th axis
Bit 5
Axis S