Spindle orientation through initiator with Marker M2501
The spindle can also be oriented through an initiator. This requires that Marker M2501 be set by the
PLC. This marker activates a spindle rotation at the speed defined in machine parameter MP3520.0
and in the direction of rotation defined in Marker M2656. If Marker M2501 is reset by the PLC (e.g.
through initiator), the spindle stops. The position value is shown in the status window. This method
can also be used to a enable a jog-mode spindle orientation.
MP3410.1 Spindle ramp slope for spindle orientation
Entry: 0.0000 to 1.9999 [V/ms]
MP3420
Positioning window for spindle
Entry: 0 to 65 535 [Increments]
1 Increment represents approx. 0.088 degrees
=
360 degrees
1024 lines
fourfold evaluation
×
MP3430
Deviation of the reference mark from the desired position (spindle preset)
Entry: 0 to 360 [degrees]
MP3440
k
v
-Factor for spindle orientation
Entry: 0.1 to 10 [
1000°/min
°
]
MP3440.0 k
v
-Factor 1st gear range
MP3440.1 k
v
-Factor 2nd gear range
MP3440.2 k
v
-Factor 3rd gear range
MP3440.3 k
v
-Factor 4th gear range
MP3440.4 k
v
-Factor 5th gear range
MP3440.5 k
v
-Factor 6th gear range
MP3440.6 k
v
-Factor 7th gear range
MP3440.7 k
v
-Factor 8th gear range
MP3520.0 Spindle speed activated by Marker M2501
Entry: 0.000 to 99 999.999 [rpm]
MP3520.1 Spindle speed for spindle orientation