background image


4-140

TNC 407/TNC 415/TNC 425

6 Display and operation

01.98

6.4.5 Control is in operation

If the control is in operation, i.e. a positioning or M-function is performed, the status window
displays a large asterisk "*". If a current NC-program is interrupted with the external stop key, the "*"
will flash in the status-display. This information is transmitted to the PLC through the markers
M2183 and M2184. M2183 and M2184 are effective in the operating modes "Positioning with MDI",
"Program run/single block" and "Program run/full sequence".

Marker

Function

Set

Reset

M2183

Program interruption (display "Control operational"

NC

NC

flashes)

M2184

Control operational (display "Control operational" on
or flashes)

6.4.6 Cancel status-display

A machine parameter can be used to decide whether with the M-functions M02 and M30, as well as
with NC-block "END PGM" the status-display should be reset and the contents of the Q-parameters
erased. All the programmed values in the status-display, e.g. tool number, tool length, tool radius,
scaling factor, datum-shift, feed-rate etc. will then be reset. The Q-parameters will all be set to 0.

MP7300

Cancel Status-display and Q-Parameters
Entry: 0 to 7

0 =

Cancel status display and Q parameters and tool data when
program is selected

1 =

Cancel status display, Q parameters and tool data with M02, M30,
END PGM and when program is selected

2 =

Cancel status display and tool data when program is selected

3 =

Cancel status display and tool data when program is selected and
with M02, M30, END PGM

4 =

Cancel status display and Q parameters when program is selected

5 =

Cancel status display and Q parameters when program is selected
and with M02, M0, END PGM

6 =

Cancel status display when program is selected

7 =

Cancel status display when program is selected and with M02, M30,
END PGM