beautypg.com

12 increment positioning – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 334

background image


01.98

TNC 407/TNC 415/TNC 425

12 Increment positioning

4-209

12 Increment positioning

In the "Electronic handwheel" mode, the function "Incremental jog positioning" can be activated by
the PLC program.

The function "Increment positioning" is enabled by marker M2498. In the "Electronic Handwheel"
mode the "Jog Increment" dialogue is displayed in addition to the "Interpolation factor" dialogue.

For increment positioning, the start marker and the corresponding complement marker for the
desired axis must be activated. If start and complement markers are not set correctly then the
message ERROR IN PLC-PROGRAM XX appears.

In the PLC program the activation of increment positioning is usually combined with the axis
direction keys (see following PLC example). The jog increment can be limited with Module 9036.

Marker

Function and entry

Error
message

Set

Reset

M2498

Enable increment positioning

PLC

PLC

M2512

Start increment positioning X+

2A

PLC

PLC

M2528

Complement increment positioning X+

M2513

Start increment positioning X-

2B

M2529

Complement increment positioning X-

M2514

Start increment positioning Y+

2C

M2530

Complement increment positioning Y+

M2515

Start increment positioning Y-

2D

M2531

Complement increment positioning Y-

M2516

Start increment positioning Z+

2E

M2532

Complement increment positioning Z+

M2517

Start increment positioning Z-

2F

M2533

Complement increment positioning Z-

M2518

Start increment positioning 4th axis+

2G

M2534

Complement increment positioning 4+

M2519

Start increment positioning 4-

2H

M2535

Complement increment positioning 4-

M2520

Start increment positioning 5+

2I

M2536

Complement increment positioning axis 5+

M2521

Start increment positioning 5-

2J

M2537

Complement increment positioning axis 5-