beautypg.com

HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 57

background image


01.98

TNC 407/TNC 415/TNC 425

5 Measuring systems

3-27

Angle encoders:

Spindle orientation:

X5

max. 30 m

LE 407

ROD 250 C
RON 255 C
ROD 700 C
RON 705 C

EXE
801

max. 50 m

Id.-Nr. 233 764..

Id.-Nr. 262 006 ..

Extension cable

5-fold

X5

max. 30 m

LE 407

ROD 250 C
RON 255 C
ROD 700 C
RON 705 C

EXE
602 E

max. 10 m

Id.-Nr. 262 004 ..

Id.-Nr. 262 006 ..

5-fold

Id.-Nr. 262 011 ..

X5

max. 20 m

LE 407

ROD 271 C
RON 275 C

Id.-Nr. 262 011 ..

X6

max. 20 m

LE

ROD 426.xxx8

1024 lines

or:

or:

Extension cable

Extension cable

Extension cable

Extension cable

Extension cable

If necessary, linear measuring systems can also be connected to the X5 connector on the LE 407 via
interpolation and digitizing electronics.

Spindle orientation