TNC 407/TNC 415/TNC 425

9 Data interface

3-41

9.2 RS-422/V.11 data interface

If used correctly, the RS-422/V.11 serial data interface will ensure error-free data transmission up to
a distance of 1000 m between logic unit and peripheral unit.

The connection to the peripheral unit is made via a cable adapter which is attached to either the
operating console or the control cabinet. See also under the heading "Mounting dimensions".

The cable adapter is connected to the logic unit with a HEIDENHAIN connecting cable.

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

X22 Data interface

RS-422/V.11

Id.-Nr. 289 208 ..

max. 1000 m

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

RS-422 Adapter Block

Id.-Nr. 249 819 01

BL

GY

WH

GN

WH/GN

GY/PK

BK

RD

PK

BN

YL

BN/GN

RD/BL

BK

BK

GND Chassis
RXD
CTS
TXD
RTS
DSR
DTR
GND Signal
RXD
CTS
TXD
RTS
DSR
DTR

The pin assignment is the same at both ends of the connecting cable.
In the RS-422 adapter the pins of the female connectors are connected one-to-one.
The pin assignment in the cable adapter is therefore the same as in the X22 connector in the logic
unit.

The following cable type must be used for the connection to the peripheral unit:
LIYCY 7 x 2 x 0.14 Cu

For the cable connection HEIDENHAIN offers a 15-pin D-subminiature connector
(Id.-Nr. 243 971 ZY).