4.2 Visual display unit (VDU)

X3 = Mains supply connection

Mains supply
voltage

110 V

220 V

Supply voltage range 85 to 132 V

170 to 264 V

Fuse rating

F 3.15 A

F 3.15 A

Frequency range

50 to 60 Hz

Power consumption

70 W

Connection

Assignment

L1

Live (BK)

N

Neutral (BL)
Protective earth (GN/YL)

X4 = DC connections (only for BC 110, Id.-Nr. 254 740 01)

Pin Number

Assignment

1

+ 24 V

2

0 V

Power supply for integral fan:
The power supply for the fan must be connected separately to the BC 110 (Id.-Nr. 254 740 01).
The connection to the +24 V machine control voltage must be according to VDE 0550.
Permissible voltage range +18 to +28 V; power consumption 5 W at +24 V DC.

The power supply for the fan is taken internally from X3 in the BC 110 B (Id.-Nr. 260 520 01). There
X4 is a DC output for test purposes (please do not connect!).