Visual display unit (vdu), 2 visual display unit (vdu) – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 49
![background image](https://www.manualsdir.com/files/815340/content/doc049.png)
4.2 Visual display unit (VDU)
X3 = Mains supply connection
Mains supply
voltage
110 V
220 V
Supply voltage range 85 to 132 V
170 to 264 V
Fuse rating
F 3.15 A
F 3.15 A
Frequency range
50 to 60 Hz
Power consumption
70 W
Connection
Assignment
L1
Live (BK)
N
Neutral (BL)
Protective earth (GN/YL)
X4 = DC connections (only for BC 110, Id.-Nr. 254 740 01)
Pin Number
Assignment
1
+ 24 V
2
0 V
Power supply for integral fan:
The power supply for the fan must be connected separately to the BC 110 (Id.-Nr. 254 740 01).
The connection to the +24 V machine control voltage must be according to VDE 0550.
Permissible voltage range +18 to +28 V; power consumption 5 W at +24 V DC.
The power supply for the fan is taken internally from X3 in the BC 110 B (Id.-Nr. 260 520 01). There
X4 is a DC output for test purposes (please do not connect!).