3 tool calibration with tt 110 – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 433
Machine
parameter
Function and input
Change
via
Reaction
Page
Feed rate reduction if stylus of the TM 110 is
deflected away from its path
Entry: 0 or 1
0 =
Feed rate reduction not active
Target window for contour-line end point
Entry: 0.1000 to 4.0000 [mm]
3.9.3 Tool calibration with TT 110
Machine
parameter
Function and input
Change
via
Reaction
Page
Tool Calibration with TT 110
Entry: 0 or 1
0 =
Cycles for tool calibration inhibited
Cycles for tool calibration not inhibited
Probing direction for tool measurement
Entry: 0 to 3
0 =
Positive probing direction in the angle
reference axis (0°axis)
Positive probing direction in the +90°-axis
Negative probing direction in the angle
reference axis (0° axis)
Negative probing direction in the +90°-axis
Calculation of the probing feed rate
Entry: 0 to 2
0 =
Calculation of the probing feed rate with
constant tolerance
Calculation of the probing feed rate with
variable tolerance
Max. permissible measuring error for tool
measurement with rotating tool
Entry: 0.002 to 0.999 [mm]
Probing feed rate for tool measurement with non-
rotating tool
Entry: 10 to 3000 [mm/min]
Diameter or edge length of TT 110 probe contact
Entry: 0.001 to 99 999.9999 [mm]
Safety zone around the probe contact TT 110 for
pre-positioning