beautypg.com

3 tool calibration with tt 110 – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 433

background image


01.98

TNC 407/TNC 415/TNC 425

3 List of machine parameters

5-31

Machine
parameter

Function and input

Change
via

Reaction

Page

MP6362

Feed rate reduction if stylus of the TM 110 is
deflected away from its path
Entry: 0 or 1
0 =

Feed rate reduction not active

1 =

Feed rate reduction active

4-191

MP6390

Target window for contour-line end point
Entry: 0.1000 to 4.0000 [mm]

4-191

3.9.3 Tool calibration with TT 110

Machine
parameter

Function and input

Change
via

Reaction

Page

MP6500

Tool Calibration with TT 110
Entry: 0 or 1
0 =

Cycles for tool calibration inhibited

1 =

Cycles for tool calibration not inhibited

4-194

MP6505

Probing direction for tool measurement
Entry: 0 to 3
0 =

Positive probing direction in the angle
reference axis (0°axis)

1 =

Positive probing direction in the +90°-axis

2 =

Negative probing direction in the angle
reference axis (0° axis)

3 =

Negative probing direction in the +90°-axis

4-194

MP6507

Calculation of the probing feed rate
Entry: 0 to 2
0 =

Calculation of the probing feed rate with
constant tolerance

1 =

Calculation of the probing feed rate with
variable tolerance

2 =

Constant probing feed rate

4-194

MP6510

Max. permissible measuring error for tool
measurement with rotating tool
Entry: 0.002 to 0.999 [mm]

4-194

MP6520

Probing feed rate for tool measurement with non-
rotating tool
Entry: 10 to 3000 [mm/min]

4-194

MP6530

Distance from tool lower edge to probe contract
upper edge for tool radius measurement
Entry: 0.001 to 99.9999 [mm]

4-194

MP6531

Diameter or edge length of TT 110 probe contact
Entry: 0.001 to 99 999.9999 [mm]

4-194

MP6540

Safety zone around the probe contact TT 110 for
pre-positioning
Entry: 0.001 to 99 999.9999 [mm]

4-194