HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 304

Example:
Enable of probing function in the PLC.
.
.
.
489
LN
I9
;I9 = 0 => TS not in holder
490
=
M2502 ;stop if stylus deflected
491
;
492
L
M2503
493
AN
I9
494
R
M2503 ;acknowledge probing cycle
495
;
496
;
497
;safety function
498
;M03/M04 deactivate if TS not in holder
499
;
500
L
M2485 ;M03 activated?
501
O
M2486 ;M04 activated?
502
AN
I9
;touch probe not in holder
503
S
M2487 ;display M05
504
R
M2485 ;deactivate M03
505
R
M2486 ;deactivate M04
506
R
M922
;clear buffered marker M03
507
R
M923
;clear buffered marker M04
508
R
M2488 ;NC stop
This manual is related to the following products: