beautypg.com

HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 304

background image


01.98

TNC 407/TNC 415/TNC 425

9 Touch probe

4-179

Example:
Enable of probing function in the PLC.

.
.
.

489

LN

I9

;I9 = 0 => TS not in holder

490

=

M2502 ;stop if stylus deflected

491

;

492

L

M2503

493

AN

I9

494

R

M2503 ;acknowledge probing cycle

495

;

496

;

497

;safety function

498

;M03/M04 deactivate if TS not in holder

499

;

500

L

M2485 ;M03 activated?

501

O

M2486 ;M04 activated?

502

AN

I9

;touch probe not in holder

503

S

M2487 ;display M05

504

R

M2485 ;deactivate M03

505

R

M2486 ;deactivate M04

506

R

M922

;clear buffered marker M03

507

R

M923

;clear buffered marker M04

508

R

M2488 ;NC stop