Marker
Function
Set
Reset
M2012
Lubrication pulse X axis, since value of MP4060.0
NC
NC
was exceeded
M2013
Lubrication pulse Y axis, since value of MP4060.1
was exceeded
M2014
Lubrication pulse Z axis, since value of MP4060.2
was exceeded
M2015
Lubrication pulse 4th axis, since value of MP4060.3
was exceeded
M2029
Lubrication pulse 5th axis, since value of MP4060.4
was exceeded
M2548
Reset of accumulated distance for
PLC
PLC
lubrication X axis
M2549
Reset of accumulated distance for
lubrication Y axis
M2550
Reset of accumulated distance for
lubrication Z axis
M2551
Reset of accumulated distance for
lubrication 4th axis
M2613
Reset of accumulated distance for
lubrication 5th axis