9 adjust the offset, 10 adjustment of the monitoring functions – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 398

16 Commissioning and start-up procedure
16.3.9 Adjust the offset
The rough offset-adjustment has already been carried out on the servo-amplifier. A fine offset-
adjustment can be performed with the offset-adjustment possibility described in the section "Servo
positioning".
16.3.10 Adjustment of the monitoring functions
Machine parameter
Function
Entry value
MP1710
Position monitoring
1.2
×
lag in rapid traverse
MP1720
Position monitoring (EMERGENCY STOP)
1.4
×
lag in rapid traverse
MP1410
Position monitoring
0.5 [mm]
MP1420
Position monitoring (EMERGENCY STOP)
10 [mm]
MP1140
Movement monitoring
0.5 [V]
MP1030
Positioning window
0.01 [mm]
MP1110
Standstill monitoring
0.2 [mm]
If the drives of the machine permit narrower limits, these may be entered.
This manual is related to the following products: