TNC 407/TNC 415/TNC 425

16 Commissioning and start-up procedure

4-273

16.3.9 Adjust the offset

The rough offset-adjustment has already been carried out on the servo-amplifier. A fine offset-
adjustment can be performed with the offset-adjustment possibility described in the section "Servo
positioning".

16.3.10 Adjustment of the monitoring functions

The following entry values are recommended for the monitoring functions (see section "Servo
positioning"):

Machine parameter

Function

Entry value

MP1710

Position monitoring

1.2

×

lag in rapid traverse

MP1720

Position monitoring (EMERGENCY STOP)

1.4

×

lag in rapid traverse

MP1410

Position monitoring

0.5 [mm]

MP1420

Position monitoring (EMERGENCY STOP)

10 [mm]

MP1140

Movement monitoring

0.5 [V]

MP1030

Positioning window

0.01 [mm]

MP1110

Standstill monitoring

0.2 [mm]

If the drives of the machine permit narrower limits, these may be entered.