beautypg.com

HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 691

background image


8-44

TNC 407/TNC 415/TNC 425

2 TNC data interfaces

01.98

Read-in all files

In this case the TNC sends a header without a program name, and the peripheral unit sends the first
file. The TNC again outputs a header without a program name, the next program is sent and so on.

Peripheral unit

.
.

.

BCC

Transmission path

TNC

.
.

.

1st line PGM1 BCC

Last line of last file

BCC

BCC

.
.

.

Last line PGM1 BCC

.
.

.

BCC

Read-in file with acknowledgement

In this mode, the TNC first of all sends a header without a program name. The peripheral unit then
starts data transfer, until it is stopped by the TNC. The TNC interrupts transfer by not sending a
positive acknowledgement (no ) and awaits acknowledgement.
If a positive acknowledgement is given then the program is read in. Otherwise a header is
immediately sent again.