beautypg.com

5 plc cycle time – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 647

background image


7-186

TNC 407/TNC 415/TNC 425

5 Compatibility with TNC 355

01.98

Marker

Function

M2667

No standstill monitoring axis 4

M2668

No standstill monitoring axis 5

M2810

Data format of a numerical value in M2560 to M2576

M2811

Data format of a numerical value in M2560 to M2576

M2812

Data format of a numerical value in M2560 to M2576

M2820

Update the central tool file

M2821

Strobe for updating the central tool file

M2822

Strobe for % factor for spindle voltage

M2823

Select ramp pairs for S analogue

5.3.5 PLC Cycle Time

The contouring controls of the TNC 355, TNC 407 and TNC 415 have different PLC cycle times. This
must be remembered when using the timers and counters.

Contouring Control

PLC Cycle Time

TNC 355 without
extended memory

20 ms

TNC 355 with
extended memory

22 ms

TNC 407

24 ms

TNC 415

20 ms