TNC 407/TNC 415/TNC 425

1 Machine axes

4-19

M555

M556

I10

M2816

M2817

M2824

1.5 Lubrication pulse

The PLC can control the lubrication of the guideway according to the distance travelled on each axis.
In the machine parameter MP4060.X the distance after which lubrication should be performed is
registered for each axis. The entry is in units of 65 536 µm.

Example:

Desired traversing distance: 100 m

Value entered =

100 000 000

µ

m

65 536

µ

m

= 1 526

If the stored path limit for an axis is exceeded, the NC sets a marker (M2012 to M2015, M2029) to
"1".

After carrying out the lubrication the PLC must reset the accumulated traverse distance (M2548 to
M2551, M2613).

MP4060

Path dependent lubrication
Entry range: 0 to 65 535 (units of 65 536 µm)

MP4060.0

X axis

MP4060.1

Y axis

MP4060.2

Z axis

MP4060.3

4th axis

MP4060.4

5th axis