beautypg.com

M2240, Oem cycle 68 inhibit, M2241 – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 702: Oem cycle 69 inhibit, M2242, Oem cycle 70 inhibit, M2243, Oem cycle 71 inhibit, M2244, Oem cycle 72 inhibit

background image


01.98

TNC 407/TNC 415/TNC 425

1 Creating OEM-cycles

9-5

MP7240

Inhibit program input for [Program name] = [OEM-cycle number in EPROM].
Input value 0 or 1
0 = inhibit
1 = not inhibit

MP7250

Difference between Q-parameter number for "DLG-CALL" and "DLG-DEF" block
in OEM-cycles.
Input range: 0 to 50

MP7251

Number of global Q parameters transferred from OEM-cycle to calling program.
Input range: 0 to 100

OEM-cycles stored in the PLC EPROM can be inhibited in the PLC program via flags M2240 to
M2271. Inhibited cycles cannot be defined in NC programs.
If programs with definitions of inhibited OEM-cycles are transferred to the control unit, an error
message "ERROR=..." is generated in the transferred program and the program cannot be executed.

Flag

Function

Set

Reset

M2240

Inhibit OEM-cycle 68

PLC

PLC

M2241

Inhibit OEM-cycle 69

PLC

PLC

M2242

Inhibit OEM-cycle 70

PLC

PLC

.

.

.

.

.

.

M2271

Inhibit OEM-cycle 99

PLC

PLC