MP7240
Inhibit program input for [Program name] = [OEM-cycle number in EPROM].
Input value 0 or 1
0 = inhibit
1 = not inhibit
MP7250
Difference between Q-parameter number for "DLG-CALL" and "DLG-DEF" block
in OEM-cycles.
Input range: 0 to 50
MP7251
Number of global Q parameters transferred from OEM-cycle to calling program.
Input range: 0 to 100
OEM-cycles stored in the PLC EPROM can be inhibited in the PLC program via flags M2240 to
M2271. Inhibited cycles cannot be defined in NC programs.
If programs with definitions of inhibited OEM-cycles are transferred to the control unit, an error
message "ERROR=..." is generated in the transferred program and the program cannot be executed.
Flag
Function
Set
Reset
M2240
Inhibit OEM-cycle 68
PLC
PLC
M2241
Inhibit OEM-cycle 69
PLC
PLC
M2242
Inhibit OEM-cycle 70
PLC
PLC
.
.
.
.
.
.
M2271
Inhibit OEM-cycle 99
PLC
PLC