HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 449

Machine
parameter
Function and input
Change
via
Reaction
Page
Machine parameter with multiple function
Entry: %x xxx xxx
Memory function for axis-direction keys
0 = not stored
1 = stored
Re-approaching the contour
0 = not active
1 = active
block scan (mid-program startup)
0 = not active
1 = active
Interruption of block scan with STOP or
M06
0 = interruption
1 = no interruption
Include programmed dwell time during
block scan
0 = include dwell time
1 = do not include dwell time
Start calculation with block scan
0 = start from cursor position
1 = start from beginning of program
Tool length for blocks with surface normal
vector
0 =
Without DR2 from the tool table
Memory test at switch-on
Entry: %xx
RAM-test
0 = Memory test at switch-on
1 = No memory test at switch-on
EPROM-test
0 = Memory test at switch-on
1 = No memory test at switch-on