HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 432
Machine
parameter
Function and input
Change
via
Reaction
Page
Rounding of decimal places
Entry: 0 to 2
0 = Output in 0.001 mm increments [1
1 = Output in 0.01 mm increments [10
2 = Output in 0.0001 mm increments [0.1
3.9.2 Digitizing with TM 110 (only with digitizing option)
Machine
parameter
Function and input
Change
via
Reaction
Page
Stylus deflection depth (measuring touch probe)
Entry: 0.1000 to 2.0000 [mm]
Counting direction of the measuring system signals
(measuring touch probe)
Entry: %xxx
Bit 0 =
Measuring the centre offset while calibrating the
TM110
Entry: 0 or 1
0 = Calibrate and measure centre offset
1 = Calibrate without measuring centre offset
Assignment of touch probe axes to the machine
axes
Entry: 0 to 2
0 =
Maximum stylus deflection (measuring touch
probe)
Entry: 0.1 to 4.000 [mm]
Probing feed rate (measuring touch probe)
Entry: 10 to 3000 [mm/min]
Rapid traverse in scanning cycle (measuring touch
probe)
Entry: 10 to 10 000 [mm/min]