9 measuring with a 3d touch probe, 6000 to 6199 6200 to 6299 – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 431
3.9 Measuring with a 3D touch probe
Machine
parameter
Function and input
Change
via
Reaction
Page
Selection of the touch probe system
Entry: 0 or 1
0 = TS 120
1 = TS 511
3.9.1 Digitizing with TS 120 (only with digitizing option)
Machine
parameter
Function and input
Change
via
Reaction
Page
Probing feed rate (triggering touch probe)
Entry: 10 to 3000 [mm/min]
Maximum measuring range
Entry: 0.001 to 99 999.9999 [mm]
Safety-clearance over measurement point
Entry: 0.001 to 99 999.9999 [mm]
Rapid traverse for probe cycle (triggering touch
probe)
Entry: 10 to 10000 [mm/min]
= Spindle orientation directly through NC
1 to 88 = Number of the M function for spindle
Number of oscillations per second in normal
direction
Entry: 0 to 65 535 [Hz]
Traverse for lubricating the probe axis at end of line
Entry: 0.000 to 99 999.999 [mm]
Time after which the probe axis must be lubricated
Entry: 0 to 65 535 [min]
Feed rate in normal direction
Entry: 0 to 1000 [mm/min]