beautypg.com

9 measuring with a 3d touch probe, 6000 to 6199 6200 to 6299 – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 431

background image


01.98

TNC 407/TNC 415/TNC 425

3 List of machine parameters

5-29

3.9 Measuring with a 3D touch probe

Machine
parameter

Function and input

Change
via

Reaction

Page

MP6010

Selection of the touch probe system
Entry: 0 or 1
0 = TS 120
1 = TS 511

PLC EDIT
CN 123

4-177

3.9.1 Digitizing with TS 120 (only with digitizing option)

Machine
parameter

Function and input

Change
via

Reaction

Page

MP6120

Probing feed rate (triggering touch probe)
Entry: 10 to 3000 [mm/min]

PLC RUN
CN 123

4-177

MP6130

Maximum measuring range
Entry: 0.001 to 99 999.9999 [mm]

PLC RUN
CN 123

4-177

MP6140

Safety-clearance over measurement point
Entry: 0.001 to 99 999.9999 [mm]

PLC RUN
CN 123

4-177

MP6150

Rapid traverse for probe cycle (triggering touch
probe)
Entry: 10 to 10000 [mm/min]

PLC RUN
CN 123

4-177

MP6160

Spindle orientation for 180

°

rotation

Entry: –1 to 88
–1

= Spindle orientation directly through NC

0

= Function not active

1 to 88 = Number of the M function for spindle

orientation by PLC

PLC RUN
CN 123

4-178

MP6200

Selection of triggering or measuring touch probe
system (only with "Digitizing with TM 110" option)
Entry: 0 or 1
0 = Triggering touch probe (e.g. TS 120)
1 = Measuring touch probe(e.g.. TM 110)

4-177

MP6210

Number of oscillations per second in normal
direction
Entry: 0 to 65 535 [Hz]

PLC RUN
CN 123

4-181

MP6220

Traverse for lubricating the probe axis at end of line
Entry: 0.000 to 99 999.999 [mm]

4-182

MP6221

Time after which the probe axis must be lubricated
Entry: 0 to 65 535 [min]

4-182

MP6230

Feed rate in normal direction
Entry: 0 to 1000 [mm/min]

PLC RUN
CN 123

4-181

MP6240

Maximum deflection of stylus
Entry: 0 to 10.000 [mm]

PLC RUN
CN 123

4-181

MP6260

Output of M90 on NC blocks of digitized data
Entry: 0 or 1
0 = no output of M90
1 = output of M90 in every NC block

PLC RUN
CN 123

4-181