beautypg.com

HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual

Page 76

background image


3-46

TNC 407/TNC 415/TNC 425

10 Handwheel input

01.98

Id.-Nr. 281 429 ..

2
1

white
white

blue
pink
red
violet
black

x

green
grey

x

yellow
white
brown

Adapter
HR 332

HR 332

max. 50 m

Id.-Nr. 274 556 ..

1
2
3
4
5
6
7
8
9

10
11
12

1
2
3
4
5
6
7
8
9

10
11
12

EM. STOP
EM. STOP
Permiss.
Perm. com.
Permiss.

6

TXD
RXD
Screen
DSR
0V
+12V

1
2
3
4
5
6
7
8
9

10
11
12

3
2
1

black
violet
red

1
2
3
4
5
6
7
8
9

bl

white

rt

brown

x

yellow
grey
green

1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

1

0V

3

+12V

±

0.6V(Uv)

5

DTR
TXD
RXD

LE
X23

HR 332

Id.-Nr. 272 292 ..
Id.-Nr. 272 291 ..

bl

white

rt

brown

x

yellow
grey
green

X23

1
2
3
4
5
6
7
8
9

The adapter has a cable with a 9-pin plug for connection to the logic unit, two terminals for the 24 V
of the EMERGENCY STOP circuit of the control (max. load 1.2 A) and 3 terminals for the enable
circuit. The enable buttons are N/O contacts (24 V/1.2 A).

HR 410
The HR 410 is a portable electronic handwheel with:

Five axis-selection keys

Traverse direction keys

Three keys with predefined traverse speeds (slow, medium, fast)

Actual-position-capture key

Three keys for machine functions to be determined by the machine tool builder

Two permissive buttons

EMERGENCY STOP button

Holding magnets

Dummy plug for EMERGENCY STOP circuit

Id. Nr. 271 958 03

In order to be able to mount the HR 410, you will need a TNC with at least software version
280 540 03, 280 560 03 0r 280 580 03.

The adapter includes plug-in terminal strips for the contacts of the EMERGENCY STOP button and
permissive button (maximum load 1.2 A).