2 compute string length (module 9071) 7-152, 6 plc window 7-152, 1 delete plc window (module 9080) 7-152 – HEIDENHAIN TNC 407 (243 020) Technical Manual User Manual
Page 613
Example:
S1
X
S0
-
P
O
S
.
:
1
2
11
1
Beispiel:
1
2
3
1
1
STACK
3
Error status after call: M3171 =
0: Number was transferred
1: Error condition see above
4.5.2 Compute String Length (Module 9071)
Computes the length of the string with the specified number in the string buffer.
Possible errors:
- The number of the source string is outside the valid range (0..3).
- The source string has been searched without an end of string (
Call:
PS
K/B/W/D
CM
9071
PL
B/W/D
Error status after call: M3171 =
0: String length was computed
1: Error conditions see above
4.6 PLC Window
4.6.1 Delete PLC Window (Module 9080)
Deletes the screen window for the PLC status display. The background color of the window is
defined in machine parameter MP7320.2 or MP7356.0.
Constraints:
- This job cannot be aborted by a CAN command during processing of the module in a SUBMIT Job.
The module is also active when the currently selected screen shows no PLC status window (e.g.
large graphic displays) or when the screen with PLC status window is in the background.
Possible errors:
- The module has not been called from a SUBMIT Job.