Autoswath sensitivity settings, Wath, Ensitivity – Ag Leader InSight Ver.8.0 Users Manual User Manual
Page 297: Ettings
![background image](/manuals/401044/297/background.png)
283
H
ARVEST
Press Next to continue.
4. Select Ground Speed Source
Select your ground speed source. If you will be using GPS as the
primary you will need to select a secondary source.
Press Finish to complete the configuration process.
A
UTO
S
WATH
S
ENSITIVITY
S
ETTINGS
The AutoSwath feature automatically increases or decreases
the swath width of the combine head according to your field's
boundaries and already-harvested areas. For a more
detailed explanation of the AutoSwath feature, see
Swath Control, Run Screen Operation” on page
.
The AutoSwath feature includes sensitivity levels, which
compensate for varying levels of GPS accuracy. To change
sensitivity levels, select the Configuration Tab, and press the
AutoSwath Settings button.
If swath adjustments are performing inaccurately, adjust the
sensitivity accordingly. Sensitivity 3 is the default setting.
Other settings include:
• Sensitivity 5
Use with RTK or DGPS sub-meter, terrain-compensated GPS.
• Sensitivity 4
Use with RTK or DGPS sub-meter GPS. Terrain compensation recommended.
• Sensitivity 3
Use with sub-meter accurate GPS.
• Sensitivity 2
Use with 1+ meter accurate GPS.
• Sensitivity 1
Swath segments are all on or all off. Use with 1+ meter accurate GPS.