165

P

LANTING

Error Message: “Voltage Error Alarm”.

Possible Cause: Occurs if the battery voltage drops below 10 volts, or rises above 15 volts.

Solution: Check tractor’s electrical system.

Error Message: “(Row #) Seed Rate Alarm”.

Possible Cause: The seed rate of one or more rows is less than the alarm threshold setting and the

corresponding transmission shaft sensor detects rotation.

Solution: Press OK to dismiss the error. If the alarm state is still present, the graph will state

the rows where the errors are occurring, and the Title Bar will flash the type of alarm.
Inspect row units to confirm that each has seed, and that all mechanical drive shaft parts
are working properly.

Note: If desired, the alarm threshold for the row unit may be set to 0%, which will silence the seed rate alarm.
However, the bar graph will continue to operate and the row will still be calculated in the planter average
population. For instructions on changing the alarm threshold, see

“KINZE Seed Monitor Alarms” on page

139

.

Error Message: “Low Down Force Air Pressure”

Possible Cause: Low pressure in the pneumatic down pressure system.

Solution: Press OK to dismiss the error. Check for air leaks and compressor failure.

Error Message: “Left (or Right) Tank Seed Level Low”.

Possible Cause: The Seed Scale weight has dropped below the user-entered threshold.

Solution: Press OK to dismiss the error. Refill the tank to clear the error completely.

Error Message: “Seed Tank Pressure Too Low”.

Possible Cause: The minimum air flow for seed delivery is not present.

Solution: Press OK to dismiss the error. Check fan on the ASD system.

Error Message: “Air Compressor Sensor Too Low.”

Possible Cause: The minimum air compressor tank pressure is not present.

Solution: Press OK to dismiss the error. Check the air compressor.