Hydraulic seed control on run screen, Planter control for hydraulic seed control, Revolution of the seed meter. see – Ag Leader InSight Ver.8.0 Users Manual User Manual
Page 163: And also, Hydraulic, Ydraulic, Ontrol on, Creen
149
P
LANTING
The AutoSwath feature for Row Shutoff configurations will
automatically turn individual planting unit sections on and
off based upon the following mapped features in a field
operation.
Entering and exiting outer field boundaries
Entering and exiting internal field boundaries
Entering and exiting mapped product recommendation
areas
Entering and exiting previously applied areas within a field
At left is an example of AutoSwath control used with a
Row Shutoff configuration.
H
YDRAULIC
S
EED
C
ONTROL ON
R
UN
S
CREEN
P
LANTER
C
ONTROL FOR
H
YDRAULIC
S
EED
C
ONTROL
The Planter Control window is where Hydraulic Seed
Control users can view or change the seed meter
calibration number. To check the Planter Control
window, press the Drive Control button on the Run
screen.
• Meter Calibration
The meter calibration setting displays the seed meter
calibration number, in seeds per revolution. You may wish
to adjust this setting according to the number of seed cells
on the seed meter. If so, use the numeric keypad to edit
this setting.
Note:
To optimize the Hydraulic Seed Control correctly, perform a seed meter calibration as
explained in
“Hydraulic Seed Control Seed Meter Calibration” on page
Note:
Prior to a Hydraulic Seed Control Seed Meter calibration, the numbers appearing in the meter
calibration setting should be appropriate for the type of planter seed meter being used. See the table
at
“Hydraulic Seed Control Seed Meter Calibration Numbers” on page
.
• Calibration button
Starts the Hydraulic Seed Control seed meter calibration procedure. For more information, see
Seed Control on Run Screen” on page
• Seed Meter Prime
Rotates the disk so that the seed meter is properly filled with seed to begin planting. For more information,
see
“Seed Meter Prime (Hydraulic Seed Control feature)” on page
Hydraulic Seed Control Seed Meter Calibration Numbers
Prior to calibrating the Hydraulic Seed Meter, the numbers that appear in the Meter Calibration box in the
Planter Control window should be similar to the numbers that appear below. If they are not, then your