beautypg.com

Control valve settings for self-propelled sprayers, Ontrol, Alve – Ag Leader InSight Ver.8.0 Users Manual User Manual

Page 289: Ettings for, Ropelled, Prayers

background image

275

A

PPLICATION

C

ONTROL

V

ALVE

S

ETTINGS FOR

S

ELF

-P

ROPELLED

S

PRAYERS

Flow Control

Valve or

Sprayer

Model (and

year if

applicable)

Control

System

PWM Frequency

Typical Gain Range

Zero Offset

Allowable Error

Valve Response 1

Valve Response 2

Response Threshold

Apache
510/710/1010/1
210 (2006 and
up)

In-line Servo

2%

100%

24%

Use a
starting
value of
5. * See
note
below.

All Case IH
sprayers when
using

AIM Command

AIM Command
Inline Servo

2%

100%

24%

3

Case IH
Surveyor with A-
post

Non-AIM
Command Mode
PWM

12-volt

122

**700-
900

35

2%

Case IH 3320

Non-AIM
Command Mode
PWM 12-volt

122

**700-
900

35

2%

Case IH 4420
with A-post

Non-AIM
Command Mode
PWM 12-volt

122

**700-
900

35

2%

Case IH 3200
(KZCO Valve)

Non-AIM
Command Mode
By-Pass Servo

2%

40%

10%

5

Case IH 4260
with Raven
valve

Non-AIM
Command Mode
By-Pass Servo

2%

100%

24%

3

Case IH 4260
with KZCO valve

Non-AIM
Command Mode
By-Pass Servo

2%

40%

10%

5

Case IH 3150
with Raven
valve

Non-AIM
Command Mode
In-Line Servo

2%

100%

24%

3