Stepper seed control meter alarms – Ag Leader InSight Ver.8.0 Users Manual User Manual
Page 176
![background image](/manuals/401044/176/background.png)
162
Solution
1. Turn the Master Switch off. Enter a manual ground speed and create a new region.
2. Increase Zero Flow Offset by 2.
3. From the Run screen, open the product application rate window, and highlight the appropriate product.
Select Manual control mode.
4. Switch the Master Switch on.
5. Press the up button one time. Now press the down button one time. The drive should be turning. If not,
repeat this procedure starting with Step 2.
Note: Zero Flow Offset should never be greater than 60. If 60 is insufficient, there must be some other
problem causing the skips. Contact Ag Leader Technical Support for further assistance.
Problem
• Hydraulic drive not shutting off properly, or minimum controllable speed is greater than specified.
Possible Cause
• Zero Flow Offset is set too high.
Confirmation Technique
1. Turn the Master Switch off. Enter a manual ground speed and create a new region.
2. From the Run screen, open the product application rate window, and highlight the appropriate product.
Select Manual control mode.
3. Switch the Master Switch on.
4. Press the up button one time. Now press the down button three times. If the drive is still turning, the
zero flow offset is likely to be too high.
Solution
1. Turn the Master Switch off. Enter a manual ground speed and enter a new region.
2. Reduce Zero Flow Offset by 2.
3. From the Run screen, open the product application rate window, and highlight the appropriate product.
Select Manual control mode.
4. Switch the Master Switch on.
5. Press the up button one time. Now press the down button three times. The drive should not be turning.
If it is, repeat this procedure, starting with step 2.
Note: Zero Flow Offset should never be less than 25. If 25 still seems as if this number is too high, there must
be some other problem. Contact Ag Leader Technical Support for further assistance.
S
TEPPER
S
EED
C
ONTROL
M
ETER
A
LARMS
Error Message: “Drive Out of Synch Error Drive #”
Possible Cause: Not enough hydraulic fluid is flowing to the seed meter.
Solution: Examine the stepper seed drive’s hydraulic components for restrictions.
- Make sure the tractor’s hydraulic outlet is turned on.
- Make sure the hydraulic flow settings are correct.
Error Message: “Drive Stalled Drive #”
Possible Cause: The hydraulic drive motor has stopped rotating.