To view the Seed Monitor Alarms window, go to
the Implement Tab, press the KINZE Planter
Monitor Setup button, and when the KINZE
Planter Monitor Setup window appears, press the
Alarms button. For more information, see
on KINZE Planter Monitor” on page
You can change the alarm threshold for each
individual row unit, or for an individual section, or
the whole planter. To change the threshold of an
alarm, highlight the row unit, then press either a
given percentage number (10%, 50%, 70%, or use
the numeric keypad to create your own value). The
alarm will then sound only when the population
drops below that numeric threshold value.
If you wish to turn the threshold of the alarm to
zero, press the Disable button.
Note: The default alarm setting is at 50%.
KINZE M
AGNETIC
C
OIL
S
PEED
S
ENSOR
C
ALIBRATION
KINZE Planter Monitor customers who have a magnetic coil speed sensor must check the Magnetic
Pickup check box on the Planter Configuration window when the first enter a configuration. This setting
should then be left unchanged. For reference, see
“KINZE Planter Configuration” on page
settings described on the following page.
These customers will need to calibrate the Magnetic Coil Speed Sensor at least once per season. To do
this, go to the Implement Tab, press the KINZE Planter Monitor Setup button, and press the Planter
Configuration button. When the Planter Configuration window appears, press the Calibrate button. The
Magnetic Coil Speed Sensor Calibration wizard appears.
1. Enter distance of calibration
a. The default distance for calibrating the magnetic coil speed sensor is 100 feet (50 meters). If you wish to
calibrate at another distance, enter the new distance.
b. Press Next to continue.
2. Drive from start to end points
a. Position the vehicle at the start marker. Press the green-colored Start button and drive the vehicle for the
predetermined distance.
b. Press Next to continue.
Note: The display must be set on 0.0 before you begin driving the calibration distance.
3. Stop at end of calibration distance
a. When the vehicle crosses the end marker of the predetermined distance, press the red-colored Stop button.
b. Press NEXT to continue.
4. Calibration complete
a. The speed sensor calibration number has been calculated from the actual distance driven.