Fertilizer default product settings (continued), John deere specific instructions, Ertilizer – Ag Leader InSight Ver.8.0 Users Manual User Manual
Page 286: Efault, Roduct, Ettings, Continued, Eere, Pecific, Nstructions
![background image](/manuals/401044/286/background.png)
272
F
ERTILIZER
D
EFAULT
P
RODUCT
S
ETTINGS
(
CONTINUED
)
J
OHN
D
EERE
S
PECIFIC
I
NSTRUCTIONS
Here are some tips to remember when operating the display in conjunction with a Spray Star control
system. Refer to the quick reference sheet PN: 2002831-38 and other sections of the user guide for
specific setup and operation instructions.
M
ASTER
S
WITCH
I
NPUT
After setting up a configuration in the display make sure to change the master switch input setting from
standard to optional. This will tell the display to read the foot pedal for the master switch input status.
M
ASTER
S
WITCH
U
SAGE
When manually shutting off all boom sections in the field, use the foot pedal switch. Leave the OEM master
switch on the hydro handle ON during field use. Using the hydro handle switch may lead to improper field
coverage, poor AutoSwath performance, and inaccurate spray records. Only use the John Deere master
switch when completely shutting down the sprayer to transport or service the machine.
D
ISPLAY
T
ARGET
R
ATE
The display must have a non-zero target rate entered in the display before the boom valves will open for
product application. Ensure that the target rate entered into the display and Spray Star match to avoid any
unwarranted alarms or warnings on the display.
D
ISPLAY
D
ATA
C
OLLECTION
The display will create a coverage map of all product application while logging actual application rate from the
product control system flow meter.
D
ISPLAY
A
UTO
S
WATH
B
OOM
S
ECTION
C
ONTROL
The display will automatically control the boom section on/off status based upon previously applied area, field
boundary, and any mapped internal field boundaries.
S
PRAY
S
TAR
A
PPLICATION
R
ATE
The display will not control the rate based upon the target rate value entered into the display. Application rate
is controlled exclusively by the Spray Star display.
S
PRAY
S
TAR
R
INSE
C
YCLE
When using the rinse cycle feature on the Spray Star, the display must have the boom sections on to allow the
Spray Star to properly run the rinse routine. To ensure that boom sections are on:
Percentage (in terms of
lbs./100 lbs.
Material
Type
Abbreviated
name for
display and
predefined
name for
SMS
N
P (P
2
O
5)
K (K
2
0)
Density
Ordinary
superphosphate
Dry
Superphosphate
0
20
0
N/A
Potassium
nitrate
Dry
Potassium
nitrate
13
0
44
N/A