beautypg.com

Ag Leader InSight Ver.8.0 Users Manual User Manual

Page 174

background image

160

version information, see the General section. Information on LED diagnostic states can be found in the
Index at

“Module LED Diagnostic States” on page

174.

Clutch Diagnostics (for Row Shutoff)

The Clutch Diagnostics Tab shows the voltage flowing from
each of the 12 pins in the Row Shutoff module.

To see more about the Row Shutoff module, see

“Row

Shutoff Configuration” on page

119

.

The bottom left-hand part of this tab shows the serial
number of the module.

Seed Diagnostics (for Seed Tube Monitor Module)

The Seed Diagnostics Tab shows row data from rows
monitored by the Seed Tube Monitor Module, including the
following:

• Row unit seeds per second

• Row unit seeds per acre

Additionally, alarms are shown in the right portion of the Seed
Diagnostics Tab. In this instance, a High Population alarm
has sounded at the Run Screen. This alarm appears in a list,
and the rows affected by the alarm appear underneath.

For more information on Seed Tube Monitor Module alarms,
see

“Seed Monitor Alarms” on page

130.

Seed Diagnostics (for KINZE Population Monitor)

The Seed Diagnostics Tab shows row data from the PMM,
including the following:

• Row unit seeds per second

• Row unit seeds per acre

• Shaft 1-4
The speed, in revolutions per minute, sent by the transmission
shaft’s drive seed meter on the planter.

• SDS Shaft 1 & 2
The SDS displays the speed of the metering auger found in the
bulk containers, in RPM.

• EdgeVac 1 & 2
The EdgeVac level is a measurement of seed meter vacuum. This measurement, shown in centimeters of
water, is displayed for each vacuum fan.

• Down Pressure
The pneumatic down pressure is a measurement of down force (shown in kilograms) that the air bag places
on the row unit.

• Magnetic Coil Pickup