Ag Leader Versa DirectCommand Planter Monitor Module Quick Reference Guides User Manual
Kinze planter monitor, Quick reference guide
![background image](/manuals/401028/1/background.png)
1
Kinze Planter Monitor
Quick Reference Guide
2006002-ENG Rev A
Start of Configuration Wizard
Planting
To create a configuration, make the following button presses to start the Configuration Wizard and then follow
the instructions given on the display.
Enter Settings
Press to Highlight Configuration
8360,1770,3dr
Planting
Configuration
Product
Check mark
the boxes
of specific
sensors that are
equipped on the
planter
Allows user to redo the
Muxbus Sensor Detection
Seed size sensitivity,
automatically adjusts
based on crop type
selected. Higher sensitivity
is used for smaller seeds.
Lower sensitivity if dust
is affecting displayed
population.
Select Row Spacing
Choose the
number of
drill shaft
RPM sensors
Choose the number of
rear row units
Choose the
number of
front “pusher”
row units
Check this box if planter is equipped with a magnetic
pickup speed sensor.
Calibrate the magnetic pickup speed sensor by driving a known distance and entering that
distance into the display. (PMM must be selected for speed source to allow calibration)
Choose desired
speed source from
drop down menu
Select the number of EdgeVac vacuum
sensors that are equipped on the planter
EdgeVac sensors should be calibrated
each season
Check this box if planter is equipped with a
tank pressure sensor Calibrate tank pressure
sensor each season
Ground Speed